2017-08-20 Welcome guest,  Sign In  |  Sign Up
Chin. Opt. Lett.
 Home  List of Issues    Issue 05 , Vol. 15 , 2017    10.3788/COL201715.051701


Experimental assessment of a 3-D plenoptic endoscopic imaging system
Hanh N. D. Le1, Ryan Decker2, Axel Krieger2, and Jin U. Kang1
1 Electrical and Computer Engineering Department, [Johns Hopkins University], Baltimore, MD 21 21 8, USA
2 [Sheikh Zayed Institute for Pediatric Surgical Innovation], Children’s National Health System, Washington, DC 2 0010, USA

Chin. Opt. Lett., 2017, 15(05): pp.051701

DOI:10.3788/COL201715.051701
Topic:Medical optics and biotechnology
Keywords(OCIS Code): 170.2150  170.4580  110.6880  120.3890  

Abstract
An endoscopic imaging system using a plenoptic technique to reconstruct 3-D information is demonstrated and analyzed in this Letter. The proposed setup integrates a clinical surgical endoscope with a plenoptic camera to achieve a depth accuracy error of about 1 mm and a precision error of about 2 mm, within a 25 mm×25 mm field of view, operating at 11 frames per second.

Copyright: © 2003-2012 . This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

 View PDF (630 KB)

Share:


Received:2016/10/10
Accepted:2017/1/24
Posted online:2017/3/1

Get Citation: Hanh N. D. Le, Ryan Decker, Axel Krieger, and Jin U. Kang, "Experimental assessment of a 3-D plenoptic endoscopic imaging system," Chin. Opt. Lett. 15(05), 051701(2017)

Note: This work was supported by the National Institute of Biomedical Imaging and Bioengineering of the National Institutes of Health under Grant no. 1R01EB020610. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health. We thank Justin Opfermann and Dr. Xinyang Liu (Children’s National Health System) for the use of their surgical endoscope.



References

1. P. Bucher, F. Pugin, S. Ostermann, F. Ris, M. Chilcott, and P. Morel, Surg. Endosc. 25, 408 (2011).

2. C. M. Kang, D. H. Kim, W. J. Lee, and H. S. Chi, Surg. Endosc. 25, 2004 (2011).

3. R. Smith, A. Day, T. Rockall, K. Ballard, M. Bailey, and I. Jourdan, Surg. Endosc. 26, 1522 (2012).

4. A. Shademan, R. S. Decker, J. D. Opfermann, S. Leonard, A. Krieger, and P. C. Kim, Sci. Transl. Med. 8, 337ra64 (2016).

5. S. Rohl, S. Bodenstedt, S. Suwelack, H. Kenngott, B. P. Müller-Stich, R. Dillmann, and S. Speidel, Med. Phys. 39, 1632 (2012).

6. N. Atzpadin, P. Kauff, and O. Schreer, IEEE Trans. Circuits Syst. Video Technol. 14, 321 (2004).

7. D. Stoyanov, M. V. Scarzanella, P. Pratt, and G. Z. Yang, Med. Image Comput. Comput. Assist. Intervention 6361, 275 (2010).

8. D. Stoyanov, Med. Image Comput. Comput. Assist. Interv. 7510, 479 (2012).

9. P. L. Chang, D. Stoyanov, A. Davison, and P. E. Edwards, Med. Image Comput. Comput. Assist. Interv. 8149, 42 (2013).

10. J. Penne, K. H?ller, M. Stürmer, T. Schrauder, A. Schneider, R. Engelbrecht, H. Feu?ner, B. Schmauss, and J. Hornegger, Med. Image Comput. Comput. Assist. Interv. 5761, 467 (2009).

11. A. Groch, A. Seitel, S. Hempel, S. Speidel, R. Engelbrecht, J. Penne, K. Holler, S. Rohl, K. Yung, S. Bodenstedt, and F. Pflaum, Proc. SPIE 7964, 796415 (2011).

12. P. Fursattel, S. Placht, C. Schaller, M. Balda, H. Hofmann, A. Maier, and C. Riess, IEEE Trans. Comput. Imaging 2, 27 (2016).

13. L. Maier-Hein, P. Mountney, A. Bartoli, H. Elhawary, D. Elson, A. Groch, A. Kolb, M. Rodrigues, J. Sorger, S. Speidel, and D. Stoyanov, Med. Image Anal. 17, 974 (2013).

14. S. Zhang, Opt. Lasers Eng. 48, 149 (2010).

15. H. Du, and Z. Wang, Opt. Lett. 32, 2438 (2007).

16. T. T. Wu, and J. Y. Qu, Opt. Express 15, 10421 (2007).

17. C. Schmalz, F. Forster, A. Schick, and E. Angelopoulou, Med. Image Anal. 16, 1063 (2012).

18. J. Yagnik, G. S. Gorthi, K. R. Ramakrishnan, and L. K. Rao, in TENCON 2005–2005 IEEE Region 10 Conference (2005), p. 1.

19. T. Hain, R. Eckhardt, K. Kunzi-Rapp, and B. Schmitz, Med. Laser Appl. 17, 55 (2002).

20. P. F. Gomes, M. Sesselmann, C. D. Faria, P. A. Araújo, and L. F. Teixeira-Salmela, J. Biomech. 43, 1215 (2010).

21. N. T. Clancy, D. Stoyanov, L. Maier-Hein, A. Groch, G. Z. Yang, and D. S. Elson, Biomed. Opt. Express 2, 3119 (2011).

22. National Instruments, “3D Imaging with NI LabVIEW,” http://www.ni.com/white-paper/14103/en/ (2016).

23. R. Rao, “Stereo and 3D vision ,” https://courses.cs.washington.edu/courses/cse455/09wi/Lects/lect16.pdf (2009).

24. H. Nguyen, Z. Wang, and J. Quisberth, Adv. Opt. Methods Exp. Mech. 3, 195 (2016).

25. T. Georgiev, and A. Lumsdaine, Proc. SPIE 8299, 829908 (2012).

26. C. Perwass, and L. Wietzke, Proc. SPIE 8291, 829108 (2012).

27. R. Decker, A. Shademan, J. Opfermann, S. Leonard, P. C. Kim, and A. Krieger, Proc. SPIE 9494, 94940B (2015).

28. A. Shademan, R. S. Decker, J. Opfermann, S. Leonard, P. C. Kim, and A. Krieger, in IEEE International Conference on Robotics and Automation (ICRA) (2016), p. 708.

29. C. Heinze, S. Spyropoulos, S. Hussmann, and C. Perwass, IEEE Trans. Instrum. Meas. 65, 1197 (2016).

30. O. Johannsen, C. Heinze, B. Goldluecke, and C. Perwa?, “On the calibration of focused plenoptic cameras,” in Time-of-Flight and Depth Imaging. Sensors, Algorithms, and Applications (Springer, 2013), p.?302.


Save this article's abstract as
Copyright©2014 Chinese Optics Letters 沪ICP备05015387